Equipped with high security + high performance DMM
AC/DC hook-up meter 600 A
  • Automatically determine AC/DC
  • The open circuit voltage maintenance of solar panels can be measured up to DC2000V (must be equipped with the optional DC high-voltage probe P2000; the host can only measure up to DC1000V)
  • Simultaneously displays the true RMS value and waveform peak value of the starting current (INRUSH)
  • Dustproof and waterproof performance: IP54
  • Supports wirelessization ~ transmit measured values ​​to smartphones or tablets (when wireless adapter Z3210 is installed)
  • Wirelessly transmit measurement data directly to Excel® sheets (when wireless adapter Z3210 is installed)
  • Harmonic analysis from the 1st to the 30th order can be performed through GENNECT Cross (when wireless adapter Z3210 is installed)
Japan HIOKI CM4371-50 AC and DC hook meter, hook meter, original company goods
Japan HIOKI CM4371-50 AC and DC hook meter, hook meter, original company goods
Japan HIOKI CM4371-50 AC and DC hook meter, hook meter, original company goods
Japan HIOKI CM4371-50 AC and DC hook meter function introduction
Japan HIOKI CM4371-50 AC and DC hook-up meter Solar power equipment maintenance
Japan HIOKI CM4371-50 AC and DC hook meter with Z3210 original adapter
Japan HIOKI CM4371-50 AC and DC hook meter 鉤錶 hook meter Z3210 generates report

Product specifications:

DC current range 20.00 A/600.0 A, basic accuracy: ±1.3% rdg. ±0.08 A (20A range)
AC current range
20.00 A/600.0 A (10~1 kHz, true RMS rectification)
Basic accuracy 45 - 66 Hz: ±1.3% rdg. ±0.08 A (at 20A)
Crest factor
20.00 A range: 7.5
600.0 A range: 3 or less
AC + DC current range
20.00 A/600.0 A (10~1 kHz, true RMS rectification)
Basic accuracy DC, 45 - 66 Hz: ±1.3% rdg. ±0.13 A (at 20A)
DC voltage range 600.0 mA~1000 V (600.0 V~2000 V when using P2000)
AC voltage range
6.000 V~1000 V, 4 ranges (15~1 kHz, true RMS rectification)
Basic accuracy 45 - 66 Hz: ±0.9% rdg. ±0.013 V (at 6V)
AC + DC voltage range
6.000V~1000V
4 ranges, basic accuracy DC, 45 - 66 Hz: ±1.0% rdg. ±0.023 V (at 6V)
Resistance range
600.0 Ω~6.000 MΩ, 5 ranges
Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Capacity range
1.000 μF~1000 μF, 4 ranges
Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency range
9.999 Hz~999.9 Hz, 3 ranges
Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
Temperature(K) -40.0~400.0 ˚C, accuracy: ±0.5% rdg. ±3.0 ˚C + plus temperature probe accuracy
Electricity test Hi: AC40 V~600 V, Lo: AC80 V~600 V, 50/60 Hz
Other functions DC power, continuity check, diode check, AC/DC automatic judgment, DC current/voltage positive/negative judgment, maximum/minimum/average/maximum peak value/minimum peak value display, low-pass filter, display Value maintenance, backlight, automatic power saving, beep, zero adjustment and others
Dust and water resistance IP54 (current measurement during storage or insulated conductors)
power supply
AA alkaline battery (LR03) ×2
About 40 hours (Z3210 is not installed), about 20 hours (Z3210 is installed and wireless communication is performed)
Other specified conditions: AC 10 A measurement, LCD backlight OFF, 23°C reference value
Measurable conductor diameter φ33 mm, clamp size: 69 W × 14 D mm
size 65 W × 215 H × 35 D mm
weight 340g
appendix
Test lead L9300 ×1, Carrying bag C0203 ×1, AA alkaline battery (LR03) ×2, Instruction manual ×2, Precautions on use ×1